Greenheck out of wall fire smoke damper
WebThis installation instruction applies to Fire Dampers and Com-bination Fire/Smoke Dampers mounted outside the plane of an UL approved fire partition. Combination Fire /Smoke Dampers are approved for use in Static or Dynamic Systems. The dampers are designed for operation in the vertical or horizontal position with blades running horizontal. WebFSDR-511. The FSDR-511 is a round combination fire smoke damper with round style blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Which damper best fits the application? Greenheck’s damper interactive selection guide removes the guesswork. Find blade type, velocity, pressure ...
Greenheck out of wall fire smoke damper
Did you know?
WebBefore the static fire dampers are installed into the wall the mullions must first be anchored into the wall. The fire dampers may then be installed into the mullion assembly. To correctly attach the mullions to the wall, follow these steps: 1. Anchor wall mullion caps to wall using 1⁄ 4-20 x 5⁄ 16 in. long flat head steel bolts and 3⁄ WebA: The damper location for all multi-blade models (FSD, SMD, VCD and DFD-210 series) is referred to as the A dimension (distance from end of sleeve to face of damper). The minimum space allowed is 182.575 millimeters (7.188 inches) and is the default in CAPS. The damper location for curtain style fire dampers (FD and DFD) is referred to as the K …
WebRound Fire and Combination Fire Smoke Dampers' (Part #481319) or "GFSD-xxx series Grille Access Out of Wall/Floor Combination Fire Smoke Dampers' (Part #472477) or 'OFSD-xxx, ODFD-xxx, and OFD-xxx Out of Wall/Floor Combination Fire Smoke and Fire Dampers' (Part #461337) for additional details. 1½ in. x 1½ in. x 2 in. minimum angle … WebModel FSDR-511 meets the requirements for fire dampers, smoke dampers, and combination fire smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, & 101 International Building Code (IBC) California State Fire Marshall (CFSM) Fire Damper Listing #3225-0981:0112 Leakage (Smoke) Damper …
WebModel OFD-150 is a static rated out of wall fire damper for use in HVAC systems that are automatically shut down in the event of a fire. This fire damper is rated for use in walls or partitions with less than 3 hour fire resistance rating and can be mounted vertically or horizontally. Removal of grille allows access to the damper and fusible ... WebDamper/sleeve assemblies must be installed in wall openings using flanges and sheet metal screws as illustrated and describe below. This method is only applicable to 11/2 hour rated damper; the 3 hour damper and dampers larger than 36 in. x 36 in. (914 mm x 914 mm) will require a minimum of 11/2 in. x 11/2 in. (38 mm x 38 mm) legs.
WebGreenheck is not responsible for any damage to, or failure of the unit caused by incorrect field wiring. To avoid causing death or serious bodily harm to building occupants, follow all instructions carefully. Dampers must close completely to preserve the integrity of the fire smoke separation. Smoke Damper Installation 2 Smoke Dampers
WebGreenheck-USA small air tentWebThe FSD-211 is a combination fire smoke damper with 3V-style blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg. Velocity: Up to 2,000 fpm. Temperature: Up to 350°F. 10-Day Fixed Lead Times on Select Configurations. Watch Now to Learn More! Certifications: solid solutions cswpWebCSFM California State Fire Marshal Fire Damper Listing (#3225-0981:0103) Leakage (Smoke) Damper Listing (#3230-0981:0104) *only availabe with fusible link Note: The frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high for lower pressure drop and improved damper … solids of revolution volume calculatorWebLeakage (Smoke) Damper Listing (#3230-0981:0104) *Width and Height dimensions furnished approximately 1⁄ 4 in. (6mm) undersize. Add blanket thickness (1⁄ 8 in. [3mm]) and sleeve thickness for overall sleeved damper dimension. Oversize wall opening as follows: Nominal damper size plus 3⁄ 8 in. (9.5mm). GFSD-211 Out of Wall Combination Fire ... small air tanks for salesolid splashes 2.0 op 01WebSSFSD-XXX, Series Fire & Combination Fire Smoke Dampers’ (Part #481318) or ‘Installation Instructions for FD, DFD, SSFD, SSDFD, & KFD Series Curtain Fire Dampers’ (Part #481324) for additional details 1. GAUGES AND LENGTHS OF FIRE DAMPER SLEEVES All fire smoke dampers must be installed in a steel sleeve of the required … small airtight ceramic containersWebThe SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg. Velocity: Up to 2000 fpm. Temperature: Up to 350°F. solid solvent example